Alkalizing Water Filtration System, white tank with black control head and black base
Alkalizing Water Filtration System
Has the manufacturer specified this configuration for your application and operating conditions?
- Worth considering for
- Project buyers who can provide a feed-water analysis and a defined treatment and flow requirement.
From $2,109.99
Archived USD price · Check today’s price with Crystal Quest.
View at Crystal Quest Read our assessmentAffiliate link. We may earn a commission if you purchase. Our disclosure
A documentation-based review of the manufacturer’s listing and specifications. How we reviewed it
Our assessment
The Alkalizing Water Filtration System belongs on a comparison list when its documented application matches your needs. The important next step is to verify the configuration and compatibility, rather than deciding from the product photograph alone.
What the listing gives you
- Configuration choices are documented
Flow Rate: 15 GPM, 20 GPM, 35 GPM, 60 GPM (all options are listed below). Control Head: Manual (Upflow)
- Supporting documents are available
The manufacturer links technical or installation documents. We have kept those references with the product research below.
- Identifiable part numbers
CQE-CO-02120A, CQE-CO-02121A, CQE-CO-02122A and 6 more. These are useful for asking the manufacturer about an exact configuration.
What deserves a closer look
- Fit comes first
Treat selection as a project specification: confirm the capacity, connections, utilities, commissioning and service requirements in writing.
- Look beyond the listed price
Compare the installed scope, maintenance support and consumables with the equipment quote. A catalog configuration may still require application-specific confirmation.
- Compare the same configuration
The source lists 9 configurations. Use the model and part-number table below so that a size, package or optional component is not mistaken for a different specification.
These are our reading of the published information and our buying considerations. They are not measured performance results.
The specifications, in context.
Values below are published by Crystal Quest. Specifications may describe different configurations; read the model labels and compare the complete source tables in the reference section.
SpecificationsOriginal technical table 1 of 1
| Specification | CQE-CO-02120A | CQE-CO-02121A | CQE-CO-02122A | CQE-CO-02123A | CQE-CO-02124A | CQE-CO-02125 | CQE-CO-02126 | CQE-CO-02127 | CQE-CO-02145 |
|---|---|---|---|---|---|---|---|---|---|
| Service Flow Rate GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 245 | 390 |
| Peak Flow GPM | 22 | 41 | 60 | 95 | 140 | 250 | 270 | 280 | 450 |
| Backwash Flow GPM | 5 | 7 | 12 | 15 | 25 | 35 | 50 | 65 | 75 |
| Pipe Size | 1" | 1.5" | 1.5" | 2" | 2" | 2" / 3" | 3" | 3" | 3" |
| Electronic Control Valve | 2510 | 2850 | 2850 | 2900 | 2900 | 3150 / 3900 | 3900 | 3900 | 3900 |
| Ionizer Multimedia | 3 ft³ | 4 ft³ | 7 ft³ | 10 ft³ | 15 ft³ | 20 ft³ | 30 ft³ | 40 ft³ | 60 ft³ |
| PSI Range | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 |
| Mineral Tank Size (in.) | 14" x 65" | 16" x 65" | 21" x 62" | 24" x 72" | 30" x 72" | 36" x 72" | 42" x 72" | 48" x 72" | 63" x 83" |
| Space Required (in.) (D x H) | 16" x 75" | 18" x 75" | 23" x 84" | 24" x 95" | 32" x 95" | 40" x 192" | 46" x 192" | 52" x 192" | 67" x 203" |
| Quartz (lbs.) | 30 | 40 | 70 | 100 | 150 | 200 | 300 | 400 | 600 |
Multi-column comparison tables are preserved in full under Manufacturer reference.
Choose the configuration carefully.
Treat selection as a project specification: confirm the capacity, connections, utilities, commissioning and service requirements in writing.
Model & part-number reference 9 configurations
This is a reference table, not an ordering form. SKU and option names are reproduced from the manufacturer snapshot.
| Configuration | Part number / SKU | Listed price (USD) |
|---|---|---|
| 15 GPM / Manual (Upflow) | CQE-CO-02120A | $2,109.99 |
| 20 GPM / Manual (Upflow) | CQE-CO-02121A | $2,759.99 |
| 35 GPM / Manual (Upflow) | CQE-CO-02122A | $3,639.99 |
| 60 GPM / Manual (Upflow) | CQE-CO-02123A | $5,319.99 |
| 75 GPM / Manual (Upflow) | CQE-CO-02124A | $8,029.99 |
| 185 GPM / Manual (Upflow) | CQE-CO-02125 | $13,249.99 |
| 200 GPM / Manual (Upflow) | CQE-CO-02126 | $17,359.99 |
| 245 GPM / Manual (Upflow) | CQE-CO-02127 | $19,599.99 |
| 390 GPM / Manual (Upflow) | CQE-CO-02145 | $26,389.99 |
Price snapshot from November 8, 2026. This is not a current offer or a stock confirmation.
Think beyond day one.
Compare the installed scope, maintenance support and consumables with the equipment quote. A catalog configuration may still require application-specific confirmation.
- Match the exact model or SKU before relying on an installation diagram or replacement schedule.
- Ask what the quoted package includes and what must be supplied separately.
- Keep the manufacturer’s operating instructions with your service and replacement records.
Documents & videos
- Calcite (Calcium Carbonate) Safety Data SheetDocument
- Magnesium Oxide Product Data SheetDocument
- Magnesium Oxide Safety Data SheetDocument
- Single Standard ConfigurationDocument
- Double Standard ConfigurationDocument
- Triple Standard ConfigurationDocument
- General Commercial Tank ManualDocument
- 2510 Control Head ManuaDocument
- lDocument
- 2850 Control Head ManualDocument
- 2900 Control Head ManualDocument
- 3900 Control Head ManualDocument
- 5600 Control Head ManualDocument
- 60 GPM Remin System SchematicDocument
Frequently asked questions
Has the manufacturer specified this configuration for your application and operating conditions?Our reading
The Alkalizing Water Filtration System belongs on a comparison list when its documented application matches your needs. The important next step is to verify the configuration and compatibility, rather than deciding from the product photograph alone.
Who is Alkalizing Water Filtration System worth considering for?Best fit
Project buyers who can provide a feed-water analysis and a defined treatment and flow requirement.
What are the configuration constraints and installation requirements?Fit & plumbing
Treat selection as a project specification: confirm the capacity, connections, utilities, commissioning and service requirements in writing.
What are the ongoing maintenance and filter replacement considerations?Ownership costs
Compare the installed scope, maintenance support and consumables with the equipment quote. A catalog configuration may still require application-specific confirmation.
Go back to the source.
The full product information below is supplied by Crystal Quest, including its own descriptions and claims. We have reorganized the typography and tables for reading. This material is separate from Elorova’s assessment.
Product overviewManufacturer material
Commercial Alkalizing Water Filtration Systems for Healthier, Better-Tasting Water
Enjoy the benefits of water that’s properly balanced in minerals and pH. An alkalizing water filtration system not only helps neutralize acidity but also infuses your water with essential minerals, such as calcium and magnesium.
Why Choose an Alkalizing Water Filter?
Maintaining the right pH in your water supply is essential for both health and hardware. When water is too acidic, it can corrode pipes and fixtures; when it’s overly alkaline, it can carry an off taste. By using our water enhancers and neutralizers, you can effectively stabilize your water’s pH, improve taste, and protect plumbing systems.
Recommended Use for Commercial Alkalizing Water Filtration Systems
Our enhancers and neutralizers are recommended to raise pH and alleviate acidity in both residential and commercial settings. If you suspect your water is too acidic, the alkalizing filtration system can help create a healthier water profile for drinking, cooking, and everyday use.
Perfect for Residential and Commercial Use
Whether you run a restaurant, manage an office building, or simply want the best drinking water, an alkalizing water filtration system ensures consistent water quality across all taps. Say goodbye to corrosion, unwanted tastes, and excessive acidity.
Key Benefits of Alkaline Water
-
Improved Taste: Balanced minerals help soften the flavor and reduce metallic or sour notes.
-
Mineral-Rich Hydration: Calcium, magnesium, and potassium can support overall wellness.
-
Corrosion Reduction: Minimizes the risk of damage to pipes and appliances.
-
Potential Health Support: Alkaline water may help balance acidity in the body, though results can vary.
How Our Alkalizing Water Filtration Systems Work
Stage 1 & 2: Special Blend of Natural Minerals and Infrared Balls
Water passes through a unique blend of natural minerals and infrared balls. This step not only begins the filtration process but also introduces beneficial minerals that help condition the water before it moves on to further treatment.
Stage 3 & 4: Natural Carbonate Media for Alkalizing and Ionizing
Next, the water is treated with a special blend of natural carbonate media that alkalizes, ionizes, and mineralizes it, raising its overall pH level. This process helps reduce acidity in the body and produces essential calcium, magnesium, and potassium ions that are easily absorbed. By the end of Stage 4, you have cleaner, better-tasting, and more balanced water.
Acidity vs. Alkalinity: Understanding pH
Acidity (Low pH)
Water with a low pH can be acidic, soft, and corrosive. While acidic water is often odorless and nearly tasteless, it typically lacks buffering minerals and can contain dissolved carbon dioxide, resulting in corrosion of fixtures and pinhole leaks in plumbing. Acidic water may also leach metals such as copper, iron, and lead, causing a metallic or sour taste and creating issues like blue or rust staining on fixtures and laundry.
Solution: Use a neutralizer to raise the pH and reduce corrosion and potential health risks.
Alkalinity (High pH)
Alkalinity is the capacity of water to neutralize acids. While it helps protect against sudden pH changes, too much alkalinity can give water an unpleasant taste and may lead to mineral buildup in pipes. Our filters contain a media blend of calcium and magnesium carbonates that dissolves slowly to boost pH naturally, making the water less corrosive. Additionally, alkaline water can help lower Oxidation Reduction Potential (ORP), which some believe offers additional health benefits.
(Note: pH stands for “potential hydrogen,” referring to the amount of hydrogen mixed with the water. The pH scale ranges from 0 to 14, with 7 being neutral, under 7 acidic, and over 7 alkaline.)
Get Started with the Right Water Solution
Ready to balance your water’s pH? Contact our team today to learn more about which Commercial Water Alkalizing system best suits your unique needs. We’ll help you create a comprehensive water treatment plan for a cleaner, healthier, and more enjoyable water supply.
If you're looking for alternative industry specific commercial systems, visit our commercial and industrial water filtration systems.
Features*
- Timer Control Valves
- Heavy duty composite fiberglass tanks
- High Flow Distributor
- All brass, motor driven control valve with fully adjustable backwash cycles
- Self-adjusting backwash controller
- Flow controller to limit backwash flow
- Engineered for commercial & industrial use
Benefits*
- Reduced water consumption
- Engineered for commercial & industrial use
Add-Ons*
- Metered Control Valve
- Backwash bypass
- 3200NT Controller
- NXT Upgrade Controller
- Duplex parallel, twin alternating, triplex (progressive)
- Optional skid mounting for tanks
*If you are interested in our available add-ons, please call to have them added to your system.
Compatible Valves:

GPM:15 - 390
Manual Upflow Head
Features:
- No electricity and no back wash
- easy operation
- can be either up or down flow simply by plumbing it backwards
- Tank Head, UPVC, 2.5"-8NPSM Opening (1" NPT IN/OUT, 1" NPT Center Riser)
- Tank Head, UPVC, 4"-8UN Opening (2" NPT IN/OUT, 1.5" NPT Center Riser)
3900 Automatic Control Head
This robust and versatile control valve is designed to provide superior performance for both filtration and softening applications. With its advanced timer and metering options, the Vtrol V39 ensures precise control and efficient water management.
Features:
- NXT Display Controller
- 3" BSP female connections and 6" tank adaptersr
- valves use all brass material
- Supports both downflow (DF) and upflow (UF) regeneration
- engineered for commercial & industrial use
Add-Ons:
- NXT Display Controller
- Meter Valves
Technical specificationsManufacturer material
| Specification | CQE-CO-02120A | CQE-CO-02121A | CQE-CO-02122A | CQE-CO-02123A | CQE-CO-02124A | CQE-CO-02125 | CQE-CO-02126 | CQE-CO-02127 | CQE-CO-02145 |
|---|---|---|---|---|---|---|---|---|---|
| Service Flow Rate GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 245 | 390 |
| Peak Flow GPM | 22 | 41 | 60 | 95 | 140 | 250 | 270 | 280 | 450 |
| Backwash Flow GPM | 5 | 7 | 12 | 15 | 25 | 35 | 50 | 65 | 75 |
| Pipe Size | 1" | 1.5" | 1.5" | 2" | 2" | 2" / 3" | 3" | 3" | 3" |
| Electronic Control Valve | 2510 | 2850 | 2850 | 2900 | 2900 | 3150 / 3900 | 3900 | 3900 | 3900 |
| Ionizer Multimedia | 3 ft³ | 4 ft³ | 7 ft³ | 10 ft³ | 15 ft³ | 20 ft³ | 30 ft³ | 40 ft³ | 60 ft³ |
| PSI Range | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 |
| Mineral Tank Size (in.) | 14" x 65" | 16" x 65" | 21" x 62" | 24" x 72" | 30" x 72" | 36" x 72" | 42" x 72" | 48" x 72" | 63" x 83" |
| Space Required (in.) (D x H) | 16" x 75" | 18" x 75" | 23" x 84" | 24" x 95" | 32" x 95" | 40" x 192" | 46" x 192" | 52" x 192" | 67" x 203" |
| Quartz (lbs.) | 30 | 40 | 70 | 100 | 150 | 200 | 300 | 400 | 600 |
Included parts & replacementsManufacturer material
| Specification | CQE-CO-02120 | CQE-CO-02121 | CQE-CO-02122 | CQE-CO-02123 | CQE-CO-02124 | CQE-CO-02125 | CQE-CO-02126 | CQE-CO-02127 | CQE-CO-02145 |
|---|---|---|---|---|---|---|---|---|---|
| GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 245 | 390 |
| Ionizer Multimedia | 3 ft³ | 4 ft³ | 7 ft³ | 10 ft³ | 15 ft³ | 20 ft³ | 30 ft³ | 40 ft³ | 50 ft³ |
| Quartz (lbs.) | 30 | 80 | 100 | 200 | 400 | 500 | 700 | 900 | 1200 |
| Filtration Media Information | ||
|---|---|---|
| Product Data Sheet | Safety Data Sheet | |
| Calcite (Calcium Carbonate) | Contact Crystal Quest | Calcite (Calcium Carbonate) Safety Data Sheet |
| Magnesium Oxide | Magnesium Oxide Product Data Sheet | Magnesium Oxide Safety Data Sheet |
Installation & maintenanceManufacturer material
| Schematic Samples | ||||||||
|---|---|---|---|---|---|---|---|---|
| Single Standard Configuration | Double Standard Configuration | Triple Standard Configuration | ||||||
| Installation Instructions | ||||||||
| SYS. INSTALLATION & OPERATION GUIDE | ||||||||
Calcite (Calcium Carbonate) Safety Data Sheet
Magnesium Oxide Product Data Sheet
Magnesium Oxide Safety Data Sheet
What this review is based on.
Elorova researched the public Crystal Quest product listing, its published configuration data, source photographs and linked documents. The source page was checked on .
We have not purchased or installed this product, conducted a laboratory evaluation, or independently confirmed the manufacturer’s treatment and certification claims. We do not copy retailer star ratings into an Elorova rating.
Original Crystal Quest product listingOur research is a snapshot. Check the merchant’s current documentation, warranty, configuration, price and delivery terms before deciding. Read our editorial policy.