4" x 40" Freshwater Reverse Osmosis Membrane, light green fiberglass element with cream end cap and label, angled view
4" x 40" Freshwater Reverse Osmosis Membrane
Can you match this part’s SKU, size and connections to the system label or manual?
- Worth considering for
- Existing system owners who can match a part number and configuration before ordering.
From $286.35
Archived USD price · Check today’s price with Crystal Quest.
View at Crystal Quest Read our assessmentAffiliate link. We may earn a commission if you purchase. Our disclosure
A documentation-based review of the manufacturer’s listing and specifications. How we reviewed it
Our assessment
The most useful starting point in this listing is its published element size: 4" x 40". That gives you a concrete detail to compare, but the decision still depends on the exact configuration and your intended use.
What the listing gives you
- Element size
4" x 40" — as listed by Crystal Quest. Use this as a comparison point for the matching model.
- Service life
2 to 3 years* — as listed by Crystal Quest. Use this as a comparison point for the matching model.
- Configuration choices are documented
Quantity: Single, Pack of 2, Pack of 4
What deserves a closer look
- Fit comes first
A similar photograph or product name does not establish compatibility. Confirm the exact part and its position in your system with Crystal Quest.
- Look beyond the listed price
Keep the original model number and replacement record. Check whether the listing describes one component, a multi-part kit or a complete system.
- Compare the same configuration
The source lists 3 configurations. Use the model and part-number table below so that a size, package or optional component is not mistaken for a different specification.
These are our reading of the published information and our buying considerations. They are not measured performance results.
The specifications, in context.
Values below are published by Crystal Quest. Specifications may describe different configurations; read the model labels and compare the complete source tables in the reference section.
- Element size
- 4" x 40"
- Service life
- 2 to 3 years*
- Operating pressure
- Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
- Maximum temperature
- 113°F (45°C)
Performance curvesOriginal technical table 1 of 5
| Feed temperature | 100 psi | 125 psi | 150 psi |
|---|---|---|---|
| 40°F (4°C) | 766 | 973 | 1,180 |
| 50°F (10°C) | 949 | 1,200 | 1,460 |
| 60°F (16°C) | 1,170 | 1,480 | 1,790 |
| 70°F (21°C) | 1,420 | 1,800 | 2,190 |
| 77°F (25°C) | 1,620 | 2,060 | 2,500 |
| 85°F (29°C) | 1,850 | 2,350 | 2,850 |
| 95°F (35°C) | 2,160 | 2,750 | 3,330 |
Performance curvesOriginal technical table 2 of 5
| Feed pressure | 50°F (10°C) | 60°F (16°C) | 77°F (25°C) |
|---|---|---|---|
| 25 psi | 180 | 221 | 309 |
| 50 psi | 436 | 536 | 747 |
| 75 psi | 693 | 851 | 1,190 |
| 100 psi | 949 | 1,170 | 1,620 |
| 125 psi | 1,200 | 1,480 | 2,060 |
| 150 psi | 1,460 | 1,790 | 2,500 |
Element specificationsOriginal technical table 3 of 5
| Specification | Value |
| Membrane type | Thin-film composite (TFC) reverse osmosis element |
| Application | Freshwater |
| Element size | 4" x 40" |
| Part number | CQE-RC-04086 |
| Listed replacement for | Whole House Reverse Osmosis System 1,800 GPD (1), 4,000 GPD (2), 5,000 GPD (3), 7,000 GPD (4); Commercial and Medical Mid-Flow RO Systems 1,800 to 7,000 GPD (quantity per system table) |
| Feed water | Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum |
| Start-up | Flush at least 1 hour; discard all permeate and concentrate from the flush |
| Service life | 2 to 3 years* |
Element specificationsOriginal technical table 4 of 5
| Rated production | 2,500 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water |
| Nominal salt rejection | 99% (96% minimum) |
| Test conditions | 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery |
| Operating pressure | Rated maximum: 600 psi; suggested operating range: 100 to 150 psi |
| Maximum temperature | 113°F (45°C) |
| pH range | Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12 |
| Free chlorine tolerance | 0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this). |
| Maximum turbidity | 1 NTU |
| Silt density index | Less than 5 SDI |
| Maximum pressure drop | 13 psi per element; 30 psi per pressure vessel |
Element specificationsOriginal technical table 5 of 5
| Total dissolved solids | Under 2,000 ppm |
| Hardness | Under 5 gpg (1,800 GPD); under 15 gpg (4,000 to 7,000 GPD) |
| Iron and manganese | Under 0.05 ppm each |
| Silica and organics | Under 1 ppm each |
| Free chlorine | None (remove upstream) |
| Feed temperature | 40°F to 105°F |
All extracted specification rows 25 rows
| Published item | Manufacturer value | Source section |
|---|---|---|
| Specification | Value | Technical specifications |
| Membrane type | Thin-film composite (TFC) reverse osmosis element | Technical specifications |
| Application | Freshwater | Technical specifications |
| Element size | 4" x 40" | Technical specifications |
| Part number | CQE-RC-04086 | Technical specifications |
| Listed replacement for | Whole House Reverse Osmosis System 1,800 GPD (1), 4,000 GPD (2), 5,000 GPD (3), 7,000 GPD (4); Commercial and Medical Mid-Flow RO Systems 1,800 to 7,000 GPD (quantity per system table) | Technical specifications |
| Feed water | Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum | Technical specifications |
| Start-up | Flush at least 1 hour; discard all permeate and concentrate from the flush | Technical specifications |
| Service life | 2 to 3 years* | Technical specifications |
| Rated production | 2,500 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water | Technical specifications |
| Nominal salt rejection | 99% (96% minimum) | Technical specifications |
| Test conditions | 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery | Technical specifications |
| Operating pressure | Rated maximum: 600 psi; suggested operating range: 100 to 150 psi | Technical specifications |
| Maximum temperature | 113°F (45°C) | Technical specifications |
| pH range | Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12 | Technical specifications |
| Free chlorine tolerance | 0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this). | Technical specifications |
| Maximum turbidity | 1 NTU | Technical specifications |
| Silt density index | Less than 5 SDI | Technical specifications |
| Maximum pressure drop | 13 psi per element; 30 psi per pressure vessel | Technical specifications |
| Total dissolved solids | Under 2,000 ppm | Technical specifications |
| Hardness | Under 5 gpg (1,800 GPD); under 15 gpg (4,000 to 7,000 GPD) | Technical specifications |
| Iron and manganese | Under 0.05 ppm each | Technical specifications |
| Silica and organics | Under 1 ppm each | Technical specifications |
| Free chlorine | None (remove upstream) | Technical specifications |
| Feed temperature | 40°F to 105°F | Technical specifications |
Multi-column comparison tables are preserved in full under Manufacturer reference.
Choose the configuration carefully.
A similar photograph or product name does not establish compatibility. Confirm the exact part and its position in your system with Crystal Quest.
Model & part-number reference 3 configurations
This is a reference table, not an ordering form. SKU and option names are reproduced from the manufacturer snapshot.
| Configuration | Part number / SKU | Listed price (USD) |
|---|---|---|
| Single | CQE-RC-04086 | $286.35 |
| Pack of 2 | CQE-RC-04086-2PK | $572.70 |
| Pack of 4 | CQE-RC-04086-4PK | $1,145.40 |
Price snapshot from November 8, 2026. This is not a current offer or a stock confirmation.
Think beyond day one.
Keep the original model number and replacement record. Check whether the listing describes one component, a multi-part kit or a complete system.
- Match the exact model or SKU before relying on an installation diagram or replacement schedule.
- Ask what the quoted package includes and what must be supplied separately.
- Keep the manufacturer’s operating instructions with your service and replacement records.
Frequently asked questions
Can you match this part’s SKU, size and connections to the system label or manual?Our reading
The most useful starting point in this listing is its published element size: 4" x 40". That gives you a concrete detail to compare, but the decision still depends on the exact configuration and your intended use.
Who is 4" x 40" Freshwater Reverse Osmosis Membrane worth considering for?Best fit
Existing system owners who can match a part number and configuration before ordering.
What are the configuration constraints and installation requirements?Fit & plumbing
A similar photograph or product name does not establish compatibility. Confirm the exact part and its position in your system with Crystal Quest.
What are the ongoing maintenance and filter replacement considerations?Ownership costs
Keep the original model number and replacement record. Check whether the listing describes one component, a multi-part kit or a complete system.
Go back to the source.
The full product information below is supplied by Crystal Quest, including its own descriptions and claims. We have reorganized the typography and tables for reading. This material is separate from Elorova’s assessment.
Product overviewManufacturer material
A large home or a business running on reverse osmosis cannot afford a slow tank refill or a creeping TDS reading. In Crystal Quest systems from 1,800 to 7,000 GPD, the 4" x 40" elements carry the whole load, so their condition decides how much purified water you get and how good it tastes.
The Crystal Quest 4" x 40" Freshwater Reverse Osmosis Membrane (CQE-RC-04086, the 4040 element size) is the replacement element listed for the 1,800, 4,000, 5,000 and 7,000 GPD Whole House Reverse Osmosis System and the same sizes of the Commercial and Medical Mid-Flow RO Systems. Because 4040 is a standard element size, it also fits other RO systems built for 4 x 40 inch membranes. It is a thin-film composite (TFC) element for pre-filtered, dechlorinated municipal or well water.
At a glance
- Counts by system: one for 1,800 GPD, two for 4,000 GPD, three for 5,000 GPD and four for 7,000 GPD on the Whole House RO
- Published with its test conditions: 99% nominal salt rejection (96% minimum) at 550 ppm, 150 psi, 77°F (25°C) and 15% recovery
- Freshwater class for feed water under 2,000 ppm TDS; brackish and seawater 4040 elements are sold separately
- Service life of 2 to 3 years; actual life depends on feed water quality, system configuration and usage
What you are looking at
The 4040 is the workhorse format of light commercial RO: a 4" diameter, 40" long spiral-wound element. Inside, many leaves of TFC membrane and mesh feed spacer are rolled around a perforated permeate tube. The larger diameter holds far more membrane than a 2.5" element of the same length, which is why one 4040 can carry an entire 1,800 GPD system. A brine seal at the inlet end keeps feed water from bypassing the element. It ships in preservative solution with core tube protectors on each end.
How it works and what keeps it working
Separation under pressure
The system pump pushes feed water across the membrane harder than the osmotic pressure created by its dissolved salts. Water molecules pass into the permeate channels; dissolved ions stay in the feed and leave as concentrate. Crystal Quest rates these elements at 150 psi operating pressure. A Crystal Quest RO system sends about 1 gallon to drain for every 1 to 3 gallons of purified water, depending on your water chemistry and setup.
Clean, then decide
Over time, mineral scale, organics and biological film build up on the membrane surface. Before replacing elements, check whether a cleaning will bring them back. Periodic cleaning can restore performance, but keep cleaning flows within the pressure-drop limits of 13 psi per element and 30 psi per pressure vessel. If rejection does not recover after cleaning, the membrane itself has aged and it is time for new elements.
What it reduces
Primary target: total dissolved solids: hardness minerals, sodium, chloride, sulfate and the other dissolved ions behind scale, spotting and off tastes. Crystal Quest whole house RO systems are rated for 96% minimum and 98.5% nominal salt rejection.
Also held back: particles of every kind, microplastics included, are far too large to pass the membrane; the pre-filters catch most of them first.
Not designed to handle: free chlorine (0.1 ppm maximum), sediment, and iron or manganese above 0.05 ppm. Feed hardness should be under 5 gpg on 1,800 GPD systems and under 15 gpg on 4,000 to 7,000 GPD systems. For salty groundwater or seawater, choose the 4" x 40" Brackish Water or 4" x 40" Seawater Desal element instead.
Why Crystal Quest
- The exact element and count for each Crystal Quest system size, from our own replacement tables.
- Expert support for big systems: help reading your log, deciding clean or replace, and setting up the system again.
- Over 1,000,000 people served since 1994. Crystal Quest builds under ISO 9001 quality management, has made water filtration in the USA for over 30 years and offers lifetime support by phone, email or chat.
Where it fits
- Whole House Reverse Osmosis System: 1,800 GPD (1), 4,000 GPD (2), 5,000 GPD (3), 7,000 GPD (4).
- Commercial Mid-Flow and Medical Mid-Flow RO Systems, 1,800 to 7,000 GPD: use the quantity in your system's replacement table.
- High-Flow RO Systems are also built on 4040 elements; call us to confirm the part for your unit.
- Smaller systems: 750, 1,500 and 2,500 GPD use the 2.5" x 40" element.
RO membranes are not returnable under our refund policy, so check the part number on your current elements or call us before ordering.
Standard 4040 format
This is a low-energy freshwater element in the standard 4040 (4" x 40") format used in 4" x 40" membrane housings and pressure vessels, including Crystal Quest systems. Crystal Quest rates its whole house RO elements at 150 psi operating pressure, well below what brackish water and seawater elements are built for, so the pump does less work on tap and well water. A shared format name is a good start, not a guarantee: if your system is not a Crystal Quest model, compare the brine seal position, permeate tube ends and flow direction with your current element, or contact us before ordering.
Storage and handling
Each element ships sealed in its bag in a preservative solution. Keep it sealed until you are ready to install it, store it indoors out of direct sunlight, and never let it freeze. Once an element has been installed and wetted, do not let it dry out. If your system will sit idle for a season, Membrane Preservative is used to protect the elements against damage from bacterial growth.
Common questions
Which systems use the 4" x 40" element?
The 1,800, 4,000, 5,000 and 7,000 GPD Whole House Reverse Osmosis System, and the same sizes of the Commercial and Medical Mid-Flow RO Systems.
How many elements do I need?
Use the count in your system's replacement table. On the Whole House Reverse Osmosis System it is one for 1,800 GPD, two for 4,000 GPD, three for 5,000 GPD and four for 7,000 GPD.
Is this a standard 4040 RO membrane?
It is a 4" x 40" element, the 4040 format. Fit is about more than the format name, so order by the part number your Crystal Quest system lists, or call us to confirm.
Should I clean or replace my 4040 membranes?
If performance dropped because of scale or fouling, a cleaning can bring it back. If rejection stays low after cleaning and fresh pre-filters, replace the elements.
How long do they last?
Plan on 2 to 3 years. Actual life depends on feed water quality, system configuration and usage.
Do I need to flush a new element?
Yes. New elements ship in a preservative solution. Flush for at least 1 hour and discard all permeate and concentrate made during the flush.
Freshwater, brackish or seawater?
This is the freshwater element. Crystal Quest also sells 4" x 40" brackish water and seawater desal elements. Choose the class your system and feed water are designed for, and ask Crystal Quest if you are unsure.
Technical specificationsManufacturer material
Specifications for your selection
Single
- SKU
- CQE-RC-04086
- Diameter (width)
- 4.0 in
- Length (height)
- 40.0 in
- Replace every
- 2 to 3 years
- Membrane type
- Thin-film composite (TFC) reverse osmosis element
- Application
- Freshwater
- Element size
- 4" x 40"
- Part number
- CQE-RC-04086
- Listed replacement for
- Whole House Reverse Osmosis System 1,800 GPD (1), 4,000 GPD (2), 5,000 GPD (3), 7,000 GPD (4); Commercial and Medical Mid-Flow RO Systems 1,800 to 7,000 GPD (quantity per system table)
- Feed water
- Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum
- Rated production
- 2,500 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water
- Nominal salt rejection
- 99% (96% minimum) at 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery
- Operating pressure
- Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
- Pressure note
- 600 psi is the element's structural limit; low energy elements are designed to make their rated flow at about 150 psi
- Maximum pressure drop
- 13 psi per element; 30 psi per pressure vessel
- Start-up
- Flush at least 1 hour; discard all permeate and concentrate from the flush
- Replacement interval
- 2 to 3 years; actual life depends on feed water quality, system configuration and usage
- Format
- Standard 4040 element; compare brine seal position and tube ends if your system is not a Crystal Quest model
- Storage
- Keep sealed until installation, out of direct sunlight; do not let it freeze, and do not let an installed element dry out
Performance curves
Rated 2,500 GPD at 77°F (25°C), 150 psi, 550 ppm feed.
Data for Figure 1
| Feed temperature | 100 psi | 125 psi | 150 psi |
|---|---|---|---|
| 40°F (4°C) | 766 | 973 | 1,180 |
| 50°F (10°C) | 949 | 1,200 | 1,460 |
| 60°F (16°C) | 1,170 | 1,480 | 1,790 |
| 70°F (21°C) | 1,420 | 1,800 | 2,190 |
| 77°F (25°C) | 1,620 | 2,060 | 2,500 |
| 85°F (29°C) | 1,850 | 2,350 | 2,850 |
| 95°F (35°C) | 2,160 | 2,750 | 3,330 |
Values in GPD (gallons per day).
Data for Figure 2
| Feed pressure | 50°F (10°C) | 60°F (16°C) | 77°F (25°C) |
|---|---|---|---|
| 25 psi | 180 | 221 | 309 |
| 50 psi | 436 | 536 | 747 |
| 75 psi | 693 | 851 | 1,190 |
| 100 psi | 949 | 1,170 | 1,620 |
| 125 psi | 1,200 | 1,480 | 2,060 |
| 150 psi | 1,460 | 1,790 | 2,500 |
Values in GPD (gallons per day).
Crystal Quest engineering data. Typical values calculated from the element's rated output at standard test conditions; actual output depends on feed water, recovery and element condition.
Element specifications
| Specification | Value |
| Membrane type | Thin-film composite (TFC) reverse osmosis element |
| Application | Freshwater |
| Element size | 4" x 40" |
| Part number | CQE-RC-04086 |
| Listed replacement for | Whole House Reverse Osmosis System 1,800 GPD (1), 4,000 GPD (2), 5,000 GPD (3), 7,000 GPD (4); Commercial and Medical Mid-Flow RO Systems 1,800 to 7,000 GPD (quantity per system table) |
| Feed water | Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum |
| Start-up | Flush at least 1 hour; discard all permeate and concentrate from the flush |
| Service life | 2 to 3 years* |
Element performance
| Rated production | 2,500 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water |
| Nominal salt rejection | 99% (96% minimum) |
| Test conditions | 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery |
| Operating pressure | Rated maximum: 600 psi; suggested operating range: 100 to 150 psi |
| Maximum temperature | 113°F (45°C) |
| pH range | Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12 |
| Free chlorine tolerance | 0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this). |
| Maximum turbidity | 1 NTU |
| Silt density index | Less than 5 SDI |
| Maximum pressure drop | 13 psi per element; 30 psi per pressure vessel |
Feed water limits for the system
| Total dissolved solids | Under 2,000 ppm |
| Hardness | Under 5 gpg (1,800 GPD); under 15 gpg (4,000 to 7,000 GPD) |
| Iron and manganese | Under 0.05 ppm each |
| Silica and organics | Under 1 ppm each |
| Free chlorine | None (remove upstream) |
| Feed temperature | 40°F to 105°F |
*Service life is an estimate. Actual life depends on feed water quality, system configuration and usage. Performance figures are from the Crystal Quest whole house RO manuals; production falls with colder or higher-TDS water. Element ratings are from the element data sheet. The 600 psi rating is the element's structural limit. Low energy elements are designed to make their rated flow at about 150 psi.

Maintenance & careManufacturer material
- When: plan on every 2 to 3 years; actual life depends on feed water quality, system configuration and usage. On well pre-treated water, rejection usually holds for two to three years, while flow can dip slightly after the first.
- Track it: log feed and product TDS, pressures and flows. Rejection = (feed TDS minus product TDS) divided by feed TDS.
- Replace as a set: on multi-element systems, change all elements together so they share the load evenly.
- Start-up and routine: flush new elements at least 1 hour, discarding permeate and concentrate, then flush the system weekly.
- Pre-filters: change them typically every 12 to 24 months, about 18 months for most homes, and yearly on chlorinated city water. The 4000/5000 GPD Whole House RO Filter Pack holds all three for those sizes.
How to replace it
- With the system shut down, remove the end caps from the top of the membrane housings (snap ring or clamp bolts, depending on the housing).
- Pull the used element out of the top of the housing; heavy-duty or channel-lock pliers may be needed.
- Open the new element bag close to the seal, then remove the element and the core tube protectors from each end.
- Inspect the brine seal and permeate tube for nicks or cuts, and replace damaged O-rings or brine seals.
- Lubricate the brine seal with a food-grade lubricant and install the brine seal end first, following the housing flow direction.
- Insert the element at a slight angle with a slow twisting motion so the brine seal stays in its groove, and push it fully into the housing.
- Refit the end caps without pinching the O-rings, reinstall the snap ring or clamp, and reconnect any fittings.
- Flush the new element for at least 1 hour, discarding all permeate and concentrate, then return the system to service as its manual directs.
Shutdowns and storage
Before a system is shipped or stored, clean it, flush it and protect the elements with a solution made for membrane elements, then drain the housings and lines completely so nothing can freeze and crack.
Plan ahead on a large system. Choose Subscribe and Save above for 7% off on the schedule you choose.
CompatibilityManufacturer material
Listed as the replacement membrane (CQE-RC-04086) for the 1,800, 4,000, 5,000 and 7,000 GPD Crystal Quest Whole House Reverse Osmosis System, which uses one, two, three and four elements respectively.
The Commercial and Medical Mid-Flow Reverse Osmosis Systems also list this element for their 1,800 to 7,000 GPD sizes. Order the quantity shown in your system's replacement table, and match diameter, length and application class.
What this review is based on.
Elorova researched the public Crystal Quest product listing, its published configuration data, source photographs and linked documents. The source page was checked on .
We have not purchased or installed this product, conducted a laboratory evaluation, or independently confirmed the manufacturer’s treatment and certification claims. We do not copy retailer star ratings into an Elorova rating.
Original Crystal Quest product listingOur research is a snapshot. Check the merchant’s current documentation, warranty, configuration, price and delivery terms before deciding. Read our editorial policy.