2.5" x 14" Freshwater Reverse Osmosis Membrane

Can you match this part’s SKU, size and connections to the system label or manual?

Worth considering for
Existing system owners who can match a part number and configuration before ordering.

From $153.75

Archived USD price · Check today’s price with Crystal Quest.

View at Crystal Quest Read our assessment

Affiliate link. We may earn a commission if you purchase. Our disclosure

A documentation-based review of the manufacturer’s listing and specifications. How we reviewed it

Our assessment

The most useful starting point in this listing is its published element size: 2.5" x 14". That gives you a concrete detail to compare, but the decision still depends on the exact configuration and your intended use.

What the listing gives you

  • Element size

    2.5" x 14" — as listed by Crystal Quest. Use this as a comparison point for the matching model.

  • Service life

    2 to 3 years* — as listed by Crystal Quest. Use this as a comparison point for the matching model.

  • Configuration choices are documented

    Quantity: Single, Pack of 2, Pack of 4

What deserves a closer look

  • Fit comes first

    A similar photograph or product name does not establish compatibility. Confirm the exact part and its position in your system with Crystal Quest.

  • Look beyond the listed price

    Keep the original model number and replacement record. Check whether the listing describes one component, a multi-part kit or a complete system.

  • Compare the same configuration

    The source lists 3 configurations. Use the model and part-number table below so that a size, package or optional component is not mistaken for a different specification.

These are our reading of the published information and our buying considerations. They are not measured performance results.

The specifications, in context.

Values below are published by Crystal Quest. Specifications may describe different configurations; read the model labels and compare the complete source tables in the reference section.

Element size
2.5" x 14"
Service life
2 to 3 years*
Operating pressure
Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
Maximum temperature
113°F (45°C)
Performance curvesOriginal technical table 1 of 5
Expected permeate flow in GPD by feed temperature and feed pressure
Feed temperature100 psi125 psi150 psi
40°F (4°C)6988106
50°F (10°C)85108131
60°F (16°C)105133161
70°F (21°C)128162197
77°F (25°C)146186225
85°F (29°C)166211256
95°F (35°C)195247300
Performance curvesOriginal technical table 2 of 5
Expected permeate flow in GPD by feed pressure and feed temperature
Feed pressure50°F (10°C)60°F (16°C)77°F (25°C)
25 psi162028
50 psi394867
75 psi6277107
100 psi85105146
125 psi108133186
150 psi131161225
Element specificationsOriginal technical table 3 of 5
Specification Value
Membrane type Thin-film composite (TFC) reverse osmosis element
Application Freshwater
Element size 2.5" x 14"
Part number CQE-RC-04111
Listed replacement for 300 GPD Whole House Reverse Osmosis System (1); 200 GPD Low-Flow Reverse Osmosis System (1)
Feed water Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum
Start-up Flush at least 1 hour; discard all permeate and concentrate from the flush
Service life 2 to 3 years*
Element specificationsOriginal technical table 4 of 5
Rated production 225 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water
Crystal Quest field results Crystal Quest tests these elements before they ship. At normal line water temperatures they produce 300 GPD or more.
Nominal salt rejection 99% (96% minimum)
Test conditions 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery
Operating pressure Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
Maximum temperature 113°F (45°C)
pH range Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12
Free chlorine tolerance 0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this).
Maximum turbidity 1 NTU
Silt density index Less than 5 SDI
Element specificationsOriginal technical table 5 of 5
Total dissolved solids Under 2,000 ppm
Hardness Under 15 gpg
Iron and manganese Under 0.05 ppm each
Silica and organics Under 1 ppm each
Free chlorine None (remove upstream)
Feed temperature 40°F to 105°F
All extracted specification rows 25 rows
Published itemManufacturer valueSource section
SpecificationValueTechnical specifications
Membrane typeThin-film composite (TFC) reverse osmosis elementTechnical specifications
ApplicationFreshwaterTechnical specifications
Element size2.5" x 14"Technical specifications
Part numberCQE-RC-04111Technical specifications
Listed replacement for300 GPD Whole House Reverse Osmosis System (1); 200 GPD Low-Flow Reverse Osmosis System (1)Technical specifications
Feed waterPre-filtered and dechlorinated; free chlorine 0.1 ppm maximumTechnical specifications
Start-upFlush at least 1 hour; discard all permeate and concentrate from the flushTechnical specifications
Service life2 to 3 years*Technical specifications
Rated production225 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier waterTechnical specifications
Crystal Quest field resultsCrystal Quest tests these elements before they ship. At normal line water temperatures they produce 300 GPD or more.Technical specifications
Nominal salt rejection99% (96% minimum)Technical specifications
Test conditions550 ppm feed, 150 psi, 77°F (25°C), 15% recoveryTechnical specifications
Operating pressureRated maximum: 600 psi; suggested operating range: 100 to 150 psiTechnical specifications
Maximum temperature113°F (45°C)Technical specifications
pH rangeRated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12Technical specifications
Free chlorine tolerance0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this).Technical specifications
Maximum turbidity1 NTUTechnical specifications
Silt density indexLess than 5 SDITechnical specifications
Total dissolved solidsUnder 2,000 ppmTechnical specifications
HardnessUnder 15 gpgTechnical specifications
Iron and manganeseUnder 0.05 ppm eachTechnical specifications
Silica and organicsUnder 1 ppm eachTechnical specifications
Free chlorineNone (remove upstream)Technical specifications
Feed temperature40°F to 105°FTechnical specifications

Multi-column comparison tables are preserved in full under Manufacturer reference.

Choose the configuration carefully.

A similar photograph or product name does not establish compatibility. Confirm the exact part and its position in your system with Crystal Quest.

Quantity
Single · Pack of 2 · Pack of 4
Model & part-number reference 3 configurations

This is a reference table, not an ordering form. SKU and option names are reproduced from the manufacturer snapshot.

ConfigurationPart number / SKUListed price (USD)
SingleCQE-RC-04111$153.75
Pack of 2CQE-RC-04111-2PK$307.50
Pack of 4CQE-RC-04111-4PK$615.00

Price snapshot from November 8, 2026. This is not a current offer or a stock confirmation.

Think beyond day one.

Keep the original model number and replacement record. Check whether the listing describes one component, a multi-part kit or a complete system.

  • Match the exact model or SKU before relying on an installation diagram or replacement schedule.
  • Ask what the quoted package includes and what must be supplied separately.
  • Keep the manufacturer’s operating instructions with your service and replacement records.

Frequently asked questions

Can you match this part’s SKU, size and connections to the system label or manual?Our reading

The most useful starting point in this listing is its published element size: 2.5" x 14". That gives you a concrete detail to compare, but the decision still depends on the exact configuration and your intended use.

Who is 2.5" x 14" Freshwater Reverse Osmosis Membrane worth considering for?Best fit

Existing system owners who can match a part number and configuration before ordering.

What are the configuration constraints and installation requirements?Fit & plumbing

A similar photograph or product name does not establish compatibility. Confirm the exact part and its position in your system with Crystal Quest.

What are the ongoing maintenance and filter replacement considerations?Ownership costs

Keep the original model number and replacement record. Check whether the listing describes one component, a multi-part kit or a complete system.

Go back to the source.

The full product information below is supplied by Crystal Quest, including its own descriptions and claims. We have reorganized the typography and tables for reading. This material is separate from Elorova’s assessment.

Product overviewManufacturer material

RO water starting to taste flat or salty? TDS meter creeping up? Production down even with fresh pre-filters? Those are the signs of a tired membrane element, the one part of a reverse osmosis system that actually separates dissolved salts and minerals from your water.

The Crystal Quest 2.5" x 14" Freshwater Reverse Osmosis Membrane (CQE-RC-04111, the 2514 element size) is the replacement element listed for the 300 GPD Crystal Quest Whole House Reverse Osmosis System and the 200 GPD Low-Flow Reverse Osmosis System. Because 2514 is a standard element size, it also fits other RO systems built for 2.5 x 14 inch membranes. It is a thin-film composite (TFC) element for municipal and well water that has been pre-filtered and dechlorinated.

At a glance

  • The exact element for your system: one per 300 GPD Whole House RO and one per 200 GPD Low-Flow RO
  • Rejection with its test conditions: 99% nominal salt rejection (96% minimum) at 550 ppm feed, 150 psi, 77°F (25°C) and 15% recovery
  • Freshwater class: for tap and well water under 2,000 ppm TDS
  • Long service life: plan on 2 to 3 years; actual life depends on feed water quality, system configuration and usage

What you are looking at

A spiral-wound cylinder. Leaves of TFC membrane are wound around a perforated center tube, with a mesh feed spacer between them to hold a flow channel open. Purified water (permeate) spirals inward and exits through the center tube; everything held back leaves the far end as concentrate. A brine seal on one end seals the element to the housing wall so all feed water passes through it, not around it. It ships in preservative solution with protectors on each end of the permeate tube. The 14" length fits only housings built for it; it is not interchangeable with 2.5" x 21" or 2.5" x 40" elements.

How a reverse osmosis membrane works

Pressure reverses osmosis

Water naturally moves across a semipermeable membrane toward the saltier side. An RO system pushes harder than that osmotic pull, forcing water molecules through the membrane while dissolved ions stay behind. Crystal Quest rates its whole house RO elements at 150 psi operating pressure.

Cross-flow keeps it clean

An RO element does not store what it removes. Feed water sweeps across the membrane and the concentrate carries rejected minerals to drain, which is why one element can run for years. It is also why every Crystal Quest RO system sends about 1 gallon to drain for every 1 to 3 gallons of purified water, depending on your water and settings.

Reading the numbers

Rejection is feed TDS minus product TDS, divided by feed TDS. Element ratings use a single element at 15% recovery so elements compare on equal terms. Colder or higher-TDS water lowers production, and RO water reads 1 to 2 pH points below the feed, because dissolved carbon dioxide passes while buffering minerals do not.

What it reduces

Primary target: total dissolved solids, the sodium, chloride, sulfate, calcium and magnesium ions behind salty or mineral taste and spotting. Crystal Quest whole house RO systems are rated for 96% minimum and 98.5% nominal salt rejection.

Also held back: particles that reach the membrane, including microplastics, are far larger than anything it lets through. The pre-filters take most of them first.

Not designed to handle: free chlorine, which attacks the TFC layer (0.1 ppm maximum); sediment, which belongs to the pre-filters; and iron or manganese above 0.05 ppm or hardness above your system's limit, which foul and scale the surface. Pre-treat these first, or ask us about a Whole House Reverse Osmosis System sized from your water test.

Why Crystal Quest

  • Matched to our own systems, straight from our replacement tables, with no cross-reference guessing.
  • Numbers you can check: rejection with its test conditions, and full operating limits in the Specifications tab.
  • Over 1,000,000 people served since 1994. Crystal Quest builds under ISO 9001 quality management, has made water filtration in the USA for over 30 years and offers lifetime support by phone, email or chat.

Where it fits

Check the part number on your current element first. RO membranes and filter cartridges are not returnable under our refund policy, so call us if you are unsure and we will confirm the part.

Standard 2514 format

This is a low-energy freshwater element in the standard 2514 (2.5" x 14") format used in 2.5" membrane housings built for 14" elements, including Crystal Quest systems. Crystal Quest rates its whole house RO elements at 150 psi operating pressure, well below what brackish water and seawater elements are built for, so the pump does less work on tap and well water. A shared format name is a good start, not a guarantee: if your system is not a Crystal Quest model, compare the brine seal position, permeate tube ends and flow direction with your current element, or contact us before ordering.

Storage and handling

Each element ships sealed in its bag in a preservative solution. Keep it sealed until you are ready to install it, store it indoors out of direct sunlight, and never let it freeze. Once an element has been installed and wetted, do not let it dry out. If your system will sit idle for a season, Membrane Preservative is used to protect the elements against damage from bacterial growth.

Common questions

Which systems use the 2.5" x 14" element?

The 300 GPD Whole House Reverse Osmosis System and the 200 GPD Low-Flow Reverse Osmosis System each use one.

Is it interchangeable with the 2.5" x 21" element?

No. The 400 GPD Whole House RO System uses the longer 2.5" x 21" element. Order the length your system lists.

How often should I replace a 2514 RO membrane?

Plan on every 2 to 3 years. Actual life depends on feed water quality, system configuration and usage. Track feed and RO water TDS so you replace it when performance drops, not on guesswork.

What salt rejection should I expect?

The element is rated for 99% nominal salt rejection (96% minimum) at 550 ppm feed, 150 psi, 77°F and 15% recovery. Your own reading will vary with your water's TDS, temperature and pressure.

Do I need to flush a new element?

Yes. New elements ship in a preservative solution. Flush for at least 1 hour and discard all permeate and concentrate made during the flush.

Can chlorinated city water go straight to the membrane?

No. The thin-film membrane tolerates no more than 0.1 ppm free chlorine, so the carbon block and SMART pre-filters must remove chlorine first. Change them on schedule to protect the element.

Is it suitable for brackish water or seawater?

This is a freshwater element. Crystal Quest sells brackish water and seawater desal elements as separate products; ask Crystal Quest which class your feed water needs.

Technical specificationsManufacturer material

Specifications for your selection

Single

SKU
CQE-RC-04111
Diameter (width)
2.5 in
Length (height)
14.0 in
Replace every
2 to 3 years
Membrane type
Thin-film composite (TFC) reverse osmosis element
Application
Freshwater
Element size
2.5" x 14"
Part number
CQE-RC-04111
Listed replacement for
300 GPD Whole House Reverse Osmosis System (1); 200 GPD Low-Flow Reverse Osmosis System (1)
Feed water
Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum
Rated production
225 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water
Nominal salt rejection
99% (96% minimum) at 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery
Crystal Quest field results
Crystal Quest tests these elements before they ship. At normal line water temperatures they produce 300 GPD or more.
Operating pressure
Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
Pressure note
600 psi is the element's structural limit; low energy elements are designed to make their rated flow at about 150 psi
Start-up
Flush at least 1 hour; discard all permeate and concentrate from the flush
Replacement interval
2 to 3 years; actual life depends on feed water quality, system configuration and usage
Format
Standard 2514 element; compare brine seal position and tube ends if your system is not a Crystal Quest model
Storage
Keep sealed until installation, out of direct sunlight; do not let it freeze, and do not let an installed element dry out

Performance curves

Rated 225 GPD at 77°F (25°C), 150 psi, 550 ppm feed.

Feed temperature
Figure 1. Permeate flow vs feed temperature at 100, 125 and 150 psi, normalized to the rated flow at 77°F (25°C) and 150 psi.
Data for Figure 1
Expected permeate flow in GPD by feed temperature and feed pressure
Feed temperature100 psi125 psi150 psi
40°F (4°C)6988106
50°F (10°C)85108131
60°F (16°C)105133161
70°F (21°C)128162197
77°F (25°C)146186225
85°F (29°C)166211256
95°F (35°C)195247300

Values in GPD (gallons per day).

Feed pressure
Figure 2. Permeate flow vs feed pressure at 50, 60 and 77°F. Flow follows net driving pressure, the feed pressure minus the feed's osmotic pressure (about 7 psi for the 550 ppm test feed). Shaded: suggested operating range, 100 to 150 psi.
Data for Figure 2
Expected permeate flow in GPD by feed pressure and feed temperature
Feed pressure50°F (10°C)60°F (16°C)77°F (25°C)
25 psi162028
50 psi394867
75 psi6277107
100 psi85105146
125 psi108133186
150 psi131161225

Values in GPD (gallons per day).

Crystal Quest engineering data. Typical values calculated from the element's rated output at standard test conditions; actual output depends on feed water, recovery and element condition.

Element specifications

Specification Value
Membrane type Thin-film composite (TFC) reverse osmosis element
Application Freshwater
Element size 2.5" x 14"
Part number CQE-RC-04111
Listed replacement for 300 GPD Whole House Reverse Osmosis System (1); 200 GPD Low-Flow Reverse Osmosis System (1)
Feed water Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum
Start-up Flush at least 1 hour; discard all permeate and concentrate from the flush
Service life 2 to 3 years*

Element performance

Rated production 225 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water
Crystal Quest field results Crystal Quest tests these elements before they ship. At normal line water temperatures they produce 300 GPD or more.
Nominal salt rejection 99% (96% minimum)
Test conditions 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery
Operating pressure Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
Maximum temperature 113°F (45°C)
pH range Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12
Free chlorine tolerance 0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this).
Maximum turbidity 1 NTU
Silt density index Less than 5 SDI

Feed water limits for the system

Total dissolved solids Under 2,000 ppm
Hardness Under 15 gpg
Iron and manganese Under 0.05 ppm each
Silica and organics Under 1 ppm each
Free chlorine None (remove upstream)
Feed temperature 40°F to 105°F

*Service life is an estimate. Actual life depends on feed water quality, system configuration and usage. Performance figures are from the Crystal Quest whole house RO manuals; production falls with colder or higher-TDS water. Element ratings are from the element data sheet. The 600 psi rating is the element's structural limit. Low energy elements are designed to make their rated flow at about 150 psi.

Illustration of a Crystal Quest freshwater reverse osmosis membrane element

Maintenance & careManufacturer material
  • When: plan on every 2 to 3 years; actual life depends on feed water quality, system configuration and usage. On well pre-treated water, rejection usually holds for two to three years while production can slip slightly after the first.
  • How to tell: compare feed and RO water TDS. Replace when rejection keeps falling, or production stays low after new pre-filters and a flush.
  • Routine: flush the system weekly and log pressures, flows and TDS.
  • Protect it: change pre-filters typically every 12 to 24 months, about 18 months for most homes, and yearly on chlorinated city water. The 200/300 GPD Whole House RO Filter Pack holds all three.

How to replace it

  1. With the system shut down, remove the end caps from the top of the membrane housings (snap ring or clamp bolts, depending on the housing).
  2. Pull the used element out of the top of the housing; heavy-duty or channel-lock pliers may be needed.
  3. Open the new element bag close to the seal, then remove the element and the core tube protectors from each end.
  4. Inspect the brine seal and permeate tube for nicks or cuts, and replace damaged O-rings or brine seals.
  5. Lubricate the brine seal with a food-grade lubricant and install the brine seal end first, following the housing flow direction.
  6. Insert the element at a slight angle with a slow twisting motion so the brine seal stays in its groove, and push it fully into the housing.
  7. Refit the end caps without pinching the O-rings, reinstall the snap ring or clamp, and reconnect any fittings.
  8. Flush the new element for at least 1 hour, discarding all permeate and concentrate, then return the system to service as its manual directs.

Never miss a change. Choose Subscribe and Save above for 7% off on the schedule you choose, and add the matching filter pack so the whole system is renewed together.

CompatibilityManufacturer material

Listed as the replacement membrane (CQE-RC-04111) for the 300 GPD Crystal Quest Whole House Reverse Osmosis System and the 200 GPD Low-Flow Reverse Osmosis System, one element in each.

Match the element diameter, length and application class to your system's replacement list. The 400 GPD Whole House RO System and the 300 GPD Low-Flow RO System use the longer 2.5" x 21" element instead.

What this review is based on.

Elorova researched the public Crystal Quest product listing, its published configuration data, source photographs and linked documents. The source page was checked on .

We have not purchased or installed this product, conducted a laboratory evaluation, or independently confirmed the manufacturer’s treatment and certification claims. We do not copy retailer star ratings into an Elorova rating.

Original Crystal Quest product listing

Our research is a snapshot. Check the merchant’s current documentation, warranty, configuration, price and delivery terms before deciding. Read our editorial policy.

2.5" x 14" Freshwater Reverse Osmosis Membrane

Crystal Quest source photography 1 / 10